Automatic Tank Gauges
Interface modules, dispenser interface module cables, and paper supplies.
The EVO™ 600 and EVO™ 6000 come standard with a power supply module and a controller module. Additional interface modules can be installed. Interface modules ordered with an EVO™ will be installed at the factory. If you would like them to not be installed, please order the spare/replacement version of the module. The following guidelines must be followed: :
Note: Do not include the Power Supply and Controller Modules when calculating total modules allowed..
The EVO™ 600 and EVO™ 6000 come standard with a power supply module and a controller module. Additional interface modules can be installed. Interface modules ordered with an EVO™ will be installed at the factory. If you would like them to not be installed, please order the spare/replacement version of the module. The following guidelines must be followed:
Existing Probe Modules | Allowable UDP Modules |
---|---|
0 | 6 |
1 | 4 |
2 | 2 |
3 | 0 |
Model Number | Description |
---|---|
FMP-485IS | RS485 module (EVO™ 600 and EVO™ 6000 only) |
FMP-UDP9 | UDP Module, 12 inputs, compatible with FMP-LL3-XXX and FMP-LL3-I probes, FMP-UHS and FMP-ULS sensors, and FMP-XXX-U sensors (EVO 600 and EVO 6000 only). |
TS-2WSNS | 12 input 2-wire sensor module, (Required for FMP-ULS, FMPUHS, TSP-HLS, and FMP-HFS sensors) |
TS-3WSNS | 8 input 3-wire sensor module, TSP-EIS, TSP-DIS, TSP-DDS, TSP-DTS, TSP-HIS, TSP-MWS and TSP-DVS sensors. Can also support 2-wire sensors |
TS-PRB | 12 input probe module, (Required for LL2 and LL3 Series Mag probes, VFM flow meters and DMS Mag sensors) |
TS-420IB | 8 input 4-20 mA module, (Required for LSU500 transducers and VPS and SCCM pressure sensors) |
-U sensors are not supported on the 2-wire or 3-wire sensor module.
Model Number | Description |
---|---|
TS-10ARLY | 6 output 10 Amp relay output module, high power dispensers and SCCM solenoids |
TS-420EXP | 8 input 4-20 mA module, LSU500E transducers and external devices |
TS-ACI | 12 input AC input module, (Required for dispenser hook inputs) |
TS-IO | Input output module, 4 output 4-20 mA, 8 input 3-240 VAC/DC |
TS-RLY | 8 output 2 Amp relay module, SCCM solenoid and STP control |
TS-RLY Module is not required for STP control when utilizing turbine pump interface (TPI) communications. The TS-420EXP module requires Controller Module software version 9.5 or greater Do not include Power Supply and Controller Module when calculating total modules allowed.
Model Number | Description |
---|---|
TSP-BDCBL | Bennett® 515 only cable |
TSP-GDCBL | Gilbarco™ cable |
TSP-GSDCBL | Gilbarco™ G-Site™ cable |
TSP-WDCBL | Wayne™ cable |
Model Number | Description |
---|---|
TS-TP2 | One box of 5 rolls of thermal printer paper for fuel management system and Tank Sentinel® consoles |
TS-TP2C | One case of 20 boxes of 5 rolls of thermal printer paper for fuel management system and Tank Sentinel® consoles |
Model Number | Description |
---|---|
TS-INKRB | TS-550 and TS-5000 ink ribbon |
TS-TP5000 | TS-550 and TS-5000 impact printer paper |
TS-TP5000C | 12 rolls of impact printer paper |
T5 Series consoles shipped after 8/2010 have thermal printers.